Energy Meter High Frequency Isolation Transformer 200 - 300Volt Accuracy 0.02
![]() |
Energy Meter High Voltage Isolation Transformer 200 - 300Volt Accuracy 0.02 KE6202 Voltage Isolation Transformer KE6202 is a 1:1 voltage isolation transformer with many secondary output that mainly used to test I-P close link energy meter. It is usually ......
Guangzhou Kingrise Enterprises Co., Ltd.
|
High Voltage Poxy Resin Cast Outdoor Electromagnetic Instrument Current Transformer
![]() |
... with IP65 waterproof connector Theory Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The most common usage of instrument transformers is to operate instruments or metering from...
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
|
SF6 Gas Insulation Inflatable Experimental High Voltage Transformer
![]() |
... supply departments and production departments. The accuracy designed and produced can be 0.05%, 0.02%, 0.01% or other. it has high voltage and high accuracy output feature , and used to accuracy calibartion test for HV voltage transformer .66~500KV can be...
WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
|
High accuracy 4-20mA 1-in-2-out Isolation Transmitter /active 4-20mA isolation transmitter
![]() |
4-20mA 1-in-2-out Isolation Transmitter /active 4-20mA isolation transmitter Application: ◆DC current/voltage signal isolation, conversion and amplification ◆Industrial field signal isolation and long distance transmission without distortion ◆Analog signal......
Isolation transmitter|isolation amplifier|analog isolation amplifier
|
6KV 10KV Class 0.05 Standard Voltage Transformer For Testing PT Tester
![]() |
...t below its accuracy level. Parameters Rated voltage ratio: 10 kV /100V, 10/√3 kV / 100/√3V , 10/√3 kV / 100/3V Rated second capacity: 0.25VA,0.08VA,0.03VA Accuracy: 0.01, 0.02, 0.05 Voltage 80%Un-120%Un: ratio error ≤0.02%, angle erro ≤0.6’...
Wuhan GDZX Power Equipment Co., Ltd
|
High Tension MV Ac Current Transformer outdoor indoor epoxy resin cast dry type 11kv 33kv 66kv
![]() |
... widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 36 kV. Remarks: Upon request we are glad to offer transformers according to other...
Shenzhen Chuangyin Co., Ltd.
|
0.01 Class Current Potential Transformer With Generator Double Stages
![]() |
...class 0.05, 0.02, 0.01 withstand voltage level Induction withstand voltage 1.2Un/1min; Secondary to Ground 2KV/1min Rated frequency 50 or 60HZ Feature 1) high accuracy and high voltage level 2) Can test 0.2 class or higher voltage transformer with 35kv,35/...
Zhengzhou Great Electric Co.,Ltd.
|
clamp on current transformer
![]() |
...transformer(specifications) Rated Primary current 1-200A Turn ratio 1:1000 1:2000 1:2500 Output 0.333V 1.5V Accuracy 0.1, 0.2 ,1.0 Class Second burden(Ohms) ≦5, ≦50 ,≧100k Dielectric Resistance 1000MOhms @ 500 Vdc Case Material Polypropylene resinUL flame retardant rating 94-V0 Voltage rank 600Vac(isolated condition), 30Vac(bareness condition) High......
Tianjin Grewin Technology Co., Ltd
|
Customized Hall Effect Current Transducer High Accuracy Grade Low Power Consumption
![]() |
... electronic measurement of DC, AC or pulsed currents. Features: Input current: 600A Power supply: ±15V ±5% Rated output voltage: 4V±1% Easy installation Can be customized High accuracy Very good linearity Optimized response time, no...
Shaanxi Shinhom Enterprise Co.,Ltd
|
HS-6303E Three Phase Standard Test Bench,0.05% Class,Max.120A current,6 Positions with Isolate Current Transformer
![]() |
HS-6303E THREE PHASE ENERGY METER TEST BENCH-16 Position SUIT FOR "CT &DC METER" & Single-phase/Three-phase meter 1.OVERVIEW HS-6303E three-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital ......